TL;DR Polypropylene containers for tissue culture take the autoclave: Eco2Box containers and filters keep their properties between -5 °C and +135 °C, and untreated vessels and covers are autoclavable at 121 °C. They are clear enough to check plantlets by eye without opening. The limits are just as plain: at most 5 uses recommended, growing brittleness, and no published light transmission figure.
Polypropylene containers for tissue culture raise three practical questions in a lab or a purchasing office: can I see my plants through the wall, what temperatures does the material take, and how often can it go through the autoclave. This page answers each one for Eco2Box containers, and says where a figure is not on file.
What is polypropylene, and why is it used for tissue culture containers?
Polypropylene is a plastic that resists autoclave temperatures, so a container made of it can be steam sterilised. Eco2Box makes its filtered range from it: a transparent polypropylene vessel and a polypropylene cover that closes hermetically and holds the filter. ECO2 nv has made these containers in Belgium since 1992, more than 30 years.
The autoclave compatibility list of the University of Utah puts it in one sentence: “Polypropylene is an inexpensive resin that can resist autoclave temperatures.” The same list rules polystyrene out for the autoclave. That difference matters within the Eco2Box range, as the table further down shows.
As a material, polypropylene is light. Its density is 0.895 to 0.93 g/cm³, below that of water, according to the encyclopedia entry on polypropylene.
How clear is a polypropylene container?
Eco2Box polypropylene vessels are clear, so plantlets can be checked by eye without opening the container. Polypropylene as a material is harder to make fully transparent than polystyrene, and ECO2 has not published a light transmission figure for the vessel wall.
What that means in practice:
- You can follow growth, rooting and visible contamination from outside, which saves an opening.
- If you move from glass or polystyrene, put a sample next to your current vessel and compare the clarity yourself. No comparison is published.
- If light level at plant height matters in your protocol, measure it inside a sample under your own lamps. No figure exists to calculate it from.
What heat range do polypropylene containers take?
Eco2Box containers and filters keep their properties between -5 °C and +135 °C. That covers a standard autoclave cycle at 121 °C and cool storage. It does not cover dry heat sterilisation above 135 °C or a freezer colder than -5 °C.
| Temperature | What it is | Source |
|---|---|---|
| -5 °C | Lower end of the range in which Eco2Box container and filter keep their properties | ECO2 product information |
| 0 °C | Below this temperature, polypropylene as a material becomes brittle | Encyclopedia entry on polypropylene |
| 85 °C | Heat resistance of the polystyrene RA trays and RDA covers, which are not polypropylene | ECO2 product specifications |
| 121 °C | Autoclave temperature for untreated polypropylene vessels and covers | ECO2 product information |
| +135 °C | Upper end of the range in which Eco2Box container and filter keep their properties | ECO2 product information |
| 160 to 166 °C | Melting range of commercial polypropylene as a material. Not a working temperature | Encyclopedia entry on polypropylene |
The two material rows are general figures for polypropylene, not measurements on Eco2Box containers. The working range to plan with is the -5 °C to +135 °C that ECO2 states.
Can you autoclave polypropylene containers, and how often?
Yes. Untreated Eco2Box polypropylene vessels and covers are autoclaved at 121 °C before first use, and we recommend at most 5 uses. The plastic takes 5 to 8 uses and never more than 10, but it becomes more brittle with each cycle, so check on your own crop that quality stays the same.
Check three things before a container goes back into use: cracks in the wall or the rim, a cover that still closes all the way round, and a filter that is intact. A container that fails one of them has reached its last cycle. This check is practical advice, not an ECO2 instruction.
ECO2 has not published a handling instruction for the autoclave itself, such as whether to sterilise vessels and covers apart or stacked. Ask before you set up a routine: the frequently asked questions give the reuse answer in ECO2’s own words.
Which Eco2Box articles should stay out of the autoclave?
Two groups stay out of the autoclave: gamma irradiated articles, which are supplied sterile and for which autoclaving is not recommended (at most 2 to 3 cycles, and the plastic becomes brittle, breaks sooner and turns yellowish), and the polystyrene RA trays and RDA covers, which are heat resistant to 85 °C only.
| Article group | Material | Autoclave at 121 °C | What to know |
|---|---|---|---|
| Filtered sets, untreated (round O95 and O118, oval OV80, rectangular TP) | Polypropylene vessel and cover, with filter | Yes, at most 5 uses recommended | Untreated, for your own autoclave |
| Gamma irradiated articles | Not listed per article | Not recommended, at most 2 to 3 cycles | Supplied sterile |
| RA trays and RDA covers | Polystyrene, no filter, not hermetic | No, heat resistant to 85 °C | Keep out of the autoclave |
Which article codes ship gamma irradiated is not published as a list. State with your order whether you want containers to autoclave yourself or containers that arrive sterile.
What does the filter cover add to a polypropylene vessel?
The cover turns a plastic box into a closed vessel with a chosen gas exchange. It closes 100% hermetically onto the vessel, which is a statement about the closure only, and with the cover closed the gas exchange runs through the depth filter in the cover.
The filter comes in four grades, L, XL, XXL and XXL+. Measured as Kv, the number of times the air space is replaced per day, round sets range from 9.87 for L to 81.35 for XXL+. Container and filter share the same -5 °C to +135 °C range, so the filter of an untreated set goes into the autoclave with its cover. The guide on choosing a filter grade covers which grade to start with.
When does a polypropylene container fit, and when not?
A polypropylene container fits when you sterilise with steam at 121 °C, want to see the plants without opening, and accept replacing containers after about 5 uses. It does not fit a process above 135 °C or a lab that needs a documented light transmission value.
It fits when:
- your sterilisation is a standard autoclave cycle, or you buy gamma irradiated containers that arrive sterile;
- visual checks from outside are part of your routine;
- you want the gas exchange set by a filter grade, not by how a lid happens to sit.
It does not fit, or needs a question first, when:
- a step in your protocol goes above 135 °C or below -5 °C;
- you need one vessel to last many more than 5 sterilisation cycles;
- you need written figures that are not published: light transmission, the resin grade, chemical resistance to a specific disinfectant, or the material of the packaging.
Frequently asked questions
Are Eco2Box containers autoclavable?
Untreated Eco2Box polypropylene vessels and covers are autoclavable at 121 °C. Gamma irradiated Eco2Box articles are supplied sterile and autoclaving them is not recommended, and the polystyrene RA trays and RDA covers are heat resistant to 85 °C only.
How many times can a polypropylene tissue culture container be autoclaved?
Eco2Box recommends at most 5 uses for its untreated polypropylene vessels and covers, and the plastic never takes more than 10. Each cycle makes the material more brittle, so inspect wall, rim, cover and filter before every reuse and retire a container that shows a crack.
Is polypropylene transparent or cloudy?
Eco2Box polypropylene vessels are clear enough to check plantlets by eye without opening. Polypropylene is in general less easily made fully transparent than polystyrene, and no light transmission figure is published for the Eco2Box wall, so judge a sample next to your current vessel.
What is the maximum temperature for polypropylene tissue culture containers?
For Eco2Box containers and filters the stated range is -5 °C to +135 °C. Polypropylene as a material melts at 160 to 166 °C, but that is a material figure and not a working temperature for a container with a filter cover.
Can I freeze polypropylene containers?
Not below -5 °C if you want Eco2Box container and filter to keep their properties: that is the lower end of the stated range.
Request a sample set or ask a question
A sample set of filtered Eco2Box containers is available on request, so you can judge clarity under your own lamps and run your own autoclave cycle (ask for untreated sets for that). Request a sample set, or ask a question about a figure you need. The O118/80 with filter and the rest of the product range list sizes per set.
Related guides: Glass or polypropylene for plant tissue culture, How many times can a polypropylene vessel be autoclaved?.
Sources checked on 20 November 2026: University of Utah autoclave compatibility list; encyclopedia entry on polypropylene for density and melting range. Eco2Box figures come from ECO2’s product specifications, product information and filter guide. Where no figure is published, the text says so.