TL;DR If the medium dries out too fast, step one filter grade down. If you see heavy condensation or glassy shoots, test one grade up. More ventilation means less condensation and a higher risk of medium drying. With Eco2Box the steps are measured: 9.87, 13.09, 15.58 and 81.35 air changes per day for L, XL, XXL and XXL+ in a round container. No drying figures per grade are published, so weigh your own vessels.
What is the trade-off between ventilation and medium drying?
More ventilation means less condensation and a higher risk of the medium drying out. That trade-off holds for every Eco2Box filter grade. Published reviews name very high humidity in the vessel as one cause of hyperhydricity (glassy, watery shoots), and give no universal humidity threshold.
Published work shows that gas exchange should be matched to the species, the stage and the medium, not maximised. The guide on which filter grade for each stage gives the starting grade. This article is about what to do when that grade turns out too dry or too wet.
Which filter grade if my medium dries out too fast?
Step one grade down. An Eco2Box set comes in four filter grades with rising gas exchange: L (white), XL (yellow), XXL (red) and XXL+ (green). If the medium dries out too fast with XXL+, the next grade to test is XXL. From XXL it is XL, and from XL it is L.
| Step down | Kv, round (per day) | Change, round | Kv, oval (per day) | Change, oval |
|---|---|---|---|---|
| XXL+ to XXL | 81.35 to 15.58 | about 81% less | 62.87 to 10.83 | about 83% less |
| XXL to XL | 15.58 to 13.09 | about 16% less | 10.83 to 9.84 | about 9% less |
| XL to L | 13.09 to 9.87 | about 25% less | 9.84 to 7.44 | about 24% less |
Kv is the number of times per day the air space in the container is replaced through the filter. The percentages are calculated from the measured Kv values. They describe air exchange, not grams of water.
The first step is not like the other two. Going from XXL+ to XXL removes about four fifths of the air exchange, and the published range has no grade between them. If XXL+ dries the medium and XXL gives condensation, the grade alone does not settle it. Check also that the grade exists for your set: the OV80 and the O95/60 come in all four grades, the O118/140 in L, XL and XXL+, and the TP2500 in L only.
Which grade if I see condensation or glassy shoots?
Test one grade up next to your current one, and expect a higher risk of the medium drying out. The Eco2Box filter guide suggests XXL as the standard for most propagation and XXL+ for fast growers, acclimatisation and hardening off.
One review of hyperhydricity names the aeration of cultivation vessels among the main factors, and a 2025 review lists vessel ventilation and gas exchange next to gelling agents, growth regulators, light and osmotic conditions. The first concludes that measures should be species-specific.
One independent study gives numbers for an Eco2Box vessel. Fayos et al. 2015 compared three containers on doubled haploid onion. Under their protocol B, with about 24 embryos per container type (23 to 26), hyperhydricity was 4.2% in the vessel with the Eco2Box green filter, against about 35% in a glass tube and in a culture box from another manufacturer, and 70.8% of plants were acclimatised against 23.1% and 52.2%. Under protocol A, with 16 to 35 embryos per container type, hyperhydricity did not differ significantly, and the other box gave the most acclimatised plants (37.5%). Plant density differed too: 4 to 6 plants per Eco2Box vessel against 2 to 3 per box of the other type. It is one study on one species, and which grade the green filter was is not confirmed.
How do I measure medium drying in my own vessels?
Weigh them. Treat the weight that a closed, filled vessel loses as water: the grams a vessel loses per week then show how fast its medium dries. Use a balance that reads to 0.1 g.
- Fill at least three vessels per grade with your normal volume of medium from one batch: the grade you use now and the grade below it.
- Add plants as in normal culture, or leave them out for a medium-only figure. Note which.
- Close the vessels and weigh each one on the first day.
- Put them on the same shelf at the same height, with the grades mixed.
- Weigh every vessel once a week without opening it, until your normal subculture date.
- Divide the loss by the starting weight of the medium. The result is the share of medium lost per week, per grade.
Are there published drying figures per filter grade?
No. ECO2 publishes the Kv value per grade, not the grams of water a medium loses per week, and we found no published figure for drying per closure type for any plant vessel. The Eco2Box brochure only notes that XXL+ lets a lot of air through the filter, which could cause dehydration.
What else changes medium drying besides the filter grade?
The conditions outside the filter. ECO2 lists five that change the real gas exchange of a vessel: the quantity and type of medium, the incubation temperature, the ventilation of the growth room, the number and size of plants per container, and temperature swings from the lighting.
| Condition | What to check before you change the grade |
|---|---|
| Quantity and type of medium | The same weekly loss is a smaller share of a larger fill volume |
| Time between subcultures | A small weekly loss adds up over a long cycle |
| Temperature swings from the lighting | Compare a shelf close to the lamps with one further away |
| Room ventilation and incubation temperature | Compare a position near the air outlet with one away from it |
| Number and size of plants | Weigh vessels at your normal plant density |
The checks in the right-hand column are practical suggestions, not measured effects. Time between subcultures is our addition to ECO2’s list.
When does more ventilation fit, and when less?
More ventilation fits cultures that grow fast or are about to leave the vessel. Less ventilation fits sensitive and slow cultures.
More ventilation fits when:
- the crop is a fast grower
- the stage is acclimatisation or hardening off (getting the plant used to normal air after the vessel)
- you see heavy condensation or glassy shoots at the current grade
Less ventilation fits when:
- the material is sensitive or slow: fine seeds, young seedlings, sensitive explants, initiation and callus
- the medium dries out before the subculture date
Frequently asked questions
Which Eco2Box filter grade dries the medium least?
The L filter (white) has the lowest gas exchange of the four Eco2Box grades: a Kv of 9.87 per day in a round container and 7.44 in the oval one. Less ventilation means a lower risk of the medium drying out. No drying figure in grams is published for any grade.
My medium dries out with the green filter. What do I change?
Test the red XXL filter next to the green XXL+. In a round Eco2Box container the Kv drops from 81.35 to 15.58 per day, about 81% less air exchange. Weigh both for a full cycle before you switch.
Is there a grade between XXL and XXL+?
No. The published Eco2Box range has four grades: L, XL, XXL and XXL+. The step from XXL to XXL+ is the largest, about 5.2 times in a round container and about 5.8 times in the oval one.
Can I use a different grade per stage?
Yes. With Eco2Box the filter grade is part of the set article, so a lab can run one grade for initiation and another for the last cycle before transfer. The filter guide suggests L for initiation and callus and XXL+ for hardening off.
How do I see condensation and drying without opening the vessel?
Eco2Box vessels are clear, so plantlets, condensation on the wall and the level of the medium can be checked by eye without opening. For a number, weigh the closed vessel every week and treat the weight it loses as water.
Test two grades side by side
Ask for two neighbouring grades in your sample set, and you can run the weighing test on your own crop before you change a whole stage. Tell us the species, the stage and what you see now, and we propose which grades to compare. Sample sets are available on request: request a sample set or ask a question. The product range shows which sets exist.
Related guides: How to prevent hyperhydricity: medium and vessel, Green or white filter: gas exchange (Kv) per Eco2Box grade.
Sources: Kv values, grade guidance and the list of outside conditions come from the ECO2 filter guide and brochure, checked 20 November 2026; percentages between grades are calculated from the Kv values. Literature read 20 November 2026: Polivanova and Bedarev 2022, Plants 11(23):3313, doi 10.3390/plants11233313; Barua, Igamberdiev and Debnath 2025, Plants 14(24):3721, doi 10.3390/plants14243721; Fayos et al. 2015, Frontiers in Plant Science 6:384, doi 10.3389/fpls.2015.00384. The weighing test is a practical suggestion, not an ECO2 procedure.